Updating MSWD Digital Kernel - PCB Version 2
============================

==============================================================================
|WARNING: IF THE WRONG FILE IS USED THEN THE PROCESSOR BOARD WILL BE DISABLED|
|*******  AND WILL NEED TO BE SENT BACK TO MCL FOR RE-PROGRAMMING.           |
|*******  YOU ARE CARRYING OUT THIS PROCEDURE AT YOUR OWN RISK.              |
==============================================================================


To update the microSwitch digital kernel to the latest version,
please follow these instructions... 

 1. Attach a computer to the programming port (on the processor card)
 2. Using Hyperterminal (or other terminal program) set comms to 38400,n,8,1
 3. Reboot the microSwitch digital - by turning the power off and on
 4. At the "Press <space> to enter kernel", press the <space bar>.
 5. The kernel ">>" prompt will appear.
 6. Type the command "VER" and press the <return key>

    If the Kernel is version 01.07 then it is the latest version and does not need to be updated
                             =====

 7. Type the command "ZEEB" and press the <return key>
 8. The message "Please download..." will appear.
 9. Download the new firmware (MSWD0107P2Kernel.bin) using "X-MODEM" protocol.
10. The process will take about 2 minutes.
11. At the end, the prompt ">>" will re-appear.
12. Type the command "STOP" and press the <return key>

Now follow the procedure for updating the firmware.


Any problems, Please contact
Phillip Clements
Marine Communications Limited
email: phil@marinex.co.uk
Tel: +44 (0)1453 732030
Fax: +44 (0)1453 873344